Funnel
Funnel
Connector Ring
Connector
pluristrainer cell strainer 1 µm
1 µm
pluristrainer cell strainer 5 µm
5 µm
pluristrainer cell strainer 10 µm
10 µm
pluristrainer cell strainer 15 µm
15 µm
pluristrainer cell strainer 20 µm
20 µm
pluristrainer cell strainer 30 µm
30 µm
pluristrainer cell strainer 40 µm
40 µm
pluristrainer cell strainer 50 µm
50 µm
pluristrainer cell strainer 60 µm
60 µm
pluristrainer cell strainer 70 µm
70 µm
pluristrainer cell strainer 85 µm
85 µm
pluristrainer cell strainer 100 µm
100 µm
pluristrainer cell strainer 150 µm
150 µm
pluristrainer cell strainer 200 µm
200 µm
pluristrainer cell strainer 300 µm
300 µm
pluristrainer cell strainer 400 µm
400 µm
pluristrainer cell strainer 500 µm
500 µm
pluristrainer cell strainer 750 µm
750 µm
pluristrainer cell strainer 1000 µm
1000 µm

pluriStrainer® 40 µm (Cell Strainer)

€55.00
All prices excl. tax, excl. shipping.
Feature-rich sieving device for filtration and purification of sample material and other biological liquids.
SKU
43-50040
Delivery between Nov 18, 2024 and Nov 19, 2024. Shipping from Germany.
quality - made in germany

  • €60.00 shipping to India | Free shipping from €600.00
  • Shipping within 1-2 business days
  • DDU - Delivered Duty Unpaid
  • Secure Payment
  • Find all ordering information here.

Details

The pluriStrainer® is a sieving device (or cell strainer) for a wide range of laboratory applications where the filtration and the purification of liquids is required. Its unique design features improved ventilation to avoid clogging for a smart sample preparation. pluriStrainer® are stackable to allow direct filtration with different mesh sizes and alsocan be inverted to recover the sieved material. For large sample volumes it can be combined with a funnel. It fits all major brand 50 mL centrifuge (conical) tubes. The combination of the pluriStrainer® and the Connector Ring allow using low pressure which supports the filtration. Furthermore it is possible to block the flow through the sieve and hold back the liquid on top of the mesh. The liquid on top of the mesh can be used for sample preparation and incubation such as tissue dissociation or the treatment of cells with cell lysis reagents (e.g. Buffer RLT, TRIzol®).

Features

pluriStrainer cell strainer

Filter
Attach pluriStrainer® to a sterile 50 mL centrifuge tube. Then, add sample material onto the strainer and filter sample

pluriStrainer cell strainer reversed

Reverse
To obtain the larger fraction, take off the pluriStrainer®, turn it upside down onto another 50 mL tube and flush back the sample from the pluriStrainer®.

pluriStrainer cell strainer

Increase sample load
With Funnel You can add up to 24 mL sample material on top.

pluriStrainer cell strainer

Stack
Stacking of pluriStrainer® with different mesh sizes allows for straining various cell sizes at the same time.

pluriStrainer cell strainer with connector ring

Flow control
Allows to control the rate of flow by opening or closing the Luer-Lock, e.g. for physical dissociation of primary tissue (brain, spleen etc.).

pluriStrainer cell strainer with connector ring and syringe

Low pressure
If you add a syringe to the Connector Ring, it is possible to force low pressure to support the straining of rough sample material while pulling the piston.

Application

  • Obtaining a real single cell suspension after digestion of mammary tissue and organoids
  • Enrichment of specific cells using pluriBead technology
  • Preparation of a single cell suspension of blood cells from bone marrow, pancreas, thymus, lymph nodes and others
  • Dissociation of cells from other primary tissue
  • Preparation of real single cell suspension for flow cytometry(FACS™)
  • Faster and easier alternative to gauze filtration
  • Sieving of complex and viscous liquids (in combination with Connector Ring & Syringe for vacuum)
  • Short time incubation of cells / cytokine (in combination with pluriBead and Connector Ring)

More Information

More Information
Delivery Time (days)1-2
Mesh Size40 µm
PackagingIndividual single packed
Colorlight blue
Flow ControlYes, in combination with Connecting Ring
Mesh FixationInjected in housing for strong hold
Fabric materialPET (Polyethylenterephthalat)
Housing MaterialLD-PE (Low Density Polyethylen)
Mesh Typewoven
HandlingExtended lip on strainer enables aseptic handling
SterilitySterile
Comparable withCorning Cell Strainer, EASYstrainer™ Cell sieve, Falcon™ cell strainer, Reversible Strainer, MACS® SmartStrainer
StabilityBuffer RLT®, TRIzol®, Isopropanol, organic solvent
CentrifugableYes
Tissue DissociationYes
DisinfectableYes, with 70% ethanol
Area of interestImmunology, Cell Biology, Plant Biology, Microbiology, Oncology, Ecology
Shipping ConditionRoom Termperature
Storage ConditionRoom Temperature
Regulatory StatementFor research use only. Not for use in diagnostic procedures,
Legal informationBuffer RLT® is a trademark of Qiagen, TRIzol® is a trademark of Molecular Research Center, Inc., FACS™ is a trademark of BD Biosciences, Corning is a registered trademark of Corning, Inc.; EASYstrainer™ is a registered trademark of Greiner Bio One International GmbH, Falcon™ Cell Strainers is a registered trademark of Corning, Inc.; MACS® SmartStrainer is a registered trademark of Miltenyi Biotec GmbH